Xu Ji

alt text 


副研究员 Tenure-Track Associate Professor

School of Computer Science and Engineering, Southeast University

No.2 Sipailou Xuanwu District, Nanjing, 210096, China

Email: xuji@seu.edu.cn

Cirriculum Vitae

Biography

I am a tenure-track associate professor in the school of computer science and engineering at Southeast University, starting from fall 2021. Before that, I was a postdoctoral researcher in CT research group in Department of Medical Physics at University of Wisconsin-Madison advised by Dr. Guang-Hong Chen and Dr. Ke Li. My research projects are related to x-ray imaging systems and algorithms. I served as an reviewer for journals including IEEE Transactions on Medical Imaging and Medical Physics. For more detailed information related to me, you can download a copy of my CV.

Education

Experience

Selected publications

Full publication list can be found in my CV or Google Scholar page

  1. X. Ji, M. Feng, K. Treb, R. Zhang, S. Schafer and Ke Li, ‘‘Development of an integrated C-arm interventional imaging system with a strip photon counting detector and a flat panel detector’’, IEEE Trans. Med. Imag. (2021).

  2. M. Feng*, X. Ji*, R. Zhang, K. Treb, A. M. Dingle and K. Li, ‘‘An experimental method to correct low-frequency concentric artifacts in photon counting CT’’, Phys. Med. Biol. 66, 175011 (2021) (*co-first author).

  3. X. Ji, K. Treb, and K. Li, ‘‘Anomalous edge response of cadmium telluride-based photon counting detectors jointly caused by high-flux radiation and inter-pixel communication’’, Phys. Med. Biol. 66, 085006 (2021).

  4. X. Ji, R. Zhang, K. Li, and G.-H. Chen, ‘‘Dual energy differential phase contrast CT (DE-DPC-CT) imaging,’’ IEEE Trans. Med. Imag. (2020).

  5. X. Ji, R. Zhang, G.-H. Chen, and K. Li, ‘‘Task-driven optimization of the non-spectral mode of photon counting CT for intracranial hemorrhage assessment,’’ Phys. Med. Biol. 64 215014 (2019).

  6. X. Ji, R. Zhang, G.-H. Chen, and K. Li, ‘‘Impact of anti-charge sharing on the zerofrequency detective quantum efficiency of CdTe-based photon counting detector system: cascaded systems analysis and experimental validation,’’ Phys. Med. Biol. 63, 095003 (2018).

  7. X. Ji, Y. Ge, R. Zhang, K. Li, and G.-H. Chen, ‘‘Studies of signal estimation bias in grating-based x-ray multicontrast imaging,’’ Med. Phys. 44: 2453-2465, (2017).

Invited talks

  1. ‘‘Statistical Properties of Grating-based X-ray Phase Contrast Imaging,’’ Presented at Shenzhen Institutes of Advanced Technology, Chinese Academy of Science (2019).

Honors and awards

Professional certifications